Plant load · B96% · 106/110
Flow · Pipeline 2138 MMcf/d
Market A$2.40/Mcf
W-18OFF → ON
Capacity · A176/180
Digital layerNetwork model · optimisation
Physical layerWells · plants · pipelines
Illustrative network
Technology

Technology & development direction

What FloLogIQ is building first, what is in development, and what is planned — stated plainly, with each capability's maturity labelled.

Maturity key
Initial FocusWhat is being built first.
In DevelopmentUnder development. Not deployed or validated.
PlannedIntended direction. Design not final.
OptionalMay be offered, depending on customer need.
01 · Initial focusInitial Focus

Economic dispatch

Choose well states, plant loading, permitted routes and market allocation together to improve the modelled daily economic return — within the operating limits the customer supplies.

OUTPUTA recommended operating plan and its economic breakdown — for operator review.
What is modelled
Well statesWhich available wells operate — ON or OFF.
Plant loadingThroughput at each plant against capacity available today.
Permitted routesOnly the connections configured as permitted.
Sales allocationVolumes to each market, with delivery commitments held.
Economics categories
  1. +Gas sales revenue
  2. +Condensate sales revenue
  3. −Royalties
  4. −Plant processing costs
  5. −Pipeline tariffs
  6. −Condensate handling / transport
  7. −Produced-water handling / disposal
  8. −Other modelled costs
  9. −Expected shut-in consequences
  10. ·Compression economicsPlanned
What limits are usedSupplied operating limits
  • Plant capacity available today
  • Pipeline capacities and restrictions
  • Well availability and production capability
  • Market delivery commitments

Limits are provided by the customer and configured per network. They are not derived from a hydraulic model today.

02 · Development direction

Where the product is heading — by maturity, not by date.

No delivery dates are implied
CAPABILITY INITIAL FOCUS IN DEVELOPMENT PLANNED OPTIONAL
Economic dispatchBaseline — described above
Initial FocusUsing supplied operating limits.
Hydraulic integrationPressures and flows
In DevelopmentWhat it would add: a check of proposed plans against network pressures and flows, rather than relying only on supplied limits. Hydraulic validation statuses (below) would become active.
Compression economicsPart of hydraulic integration
depends on
PlannedWhat it would add: compression effects and costs included in plan economics.
ForecastingForward-looking inputs
OptionalWhat it would add: planning beyond today's conditions, where customers want it.
03 · Hydraulic validation status

One label tells you what physics a plan was checked against.

Every recommendation carries a hydraulic status. Today, recommendations use supplied operating limits — so that is the only status in use. The others are reserved for when hydraulic integration is deployed.

Not Evaluated No hydraulic check has been run for this plan. RESERVED
Using Supplied Operating Limits The plan respects customer-supplied limits. Pressures were not modelled. IN USE TODAY · DEFAULT
Evaluation Running A hydraulic check of the plan is in progress. RESERVED
Validated The hydraulic check found the plan feasible. RESERVED
Constraint Identified The check found a limit the plan would exceed. RESERVED
Model Unavailable The hydraulic model could not be reached for this run. RESERVED
04 · Data & deployment principles

Configured for your network. Controlled by your team.

Customer-configured network

Wells, gathering, plants, routes and markets are configured for each customer. Networks shown on this site are illustrative.

Configured Data SourceConfigured Data Source

Configured Data Sources

Inputs come from sources agreed with each customer. Integrations are to be confirmed per customer — none are claimed here.

Decision record

Each run keeps its inputs, the recommendation, any overrides with reasons, and who approved the plan.

Operator control

Recommendations only. FloLogIQ does not control wells, valves or equipment; field execution stays with your team and existing systems.

Development-direction capabilities are not yet deployed or validated. They are shown to describe where the product is heading.

Discuss what a pilot could test on your network.

We'll be clear about what is available today and what is still in development.

Discuss a Pilot